How do you ignite a pilot light on a furnace

Once the gas has had time to dissipate, turn the knob to “Pilot.” Then, hold down the “Reset” button and bring the flame of a long lighter close to the pilot light opening. This should light the furnace pilot light. Once you are sure the pilot light is on, release your pressure on the reset button.

How do you turn on a pilot light?

Turn the gas regulator valve to the “pilot” position. If the water heater has a manual “ignite” button, press that to light the pilot. If it doesn’t have the button, or the button fails, press the regulator valve and hold a grill lighter or long match to the pilot light valve until the pilot ignites.

What would cause a pilot light to keep going out?

A faulty, misaligned, dirty, or damaged thermocouple is often the culprit behind your pilot light going out. The thermocouple is an automatic safety shutoff device that prevents the gas valve from opening if the pilot light is out.

How do you light a gas water heater with an electric pilot?

Turn the gas knob to “Pilot,” press and hold it down. This will start the flow of gas so you can light the flame. Some water heaters have a separate button for pilot mode, usually a red one, which you’ll press and hold. While still holding the gas down, light that pilot.

How do I reset my Honeywell gas control valve?

8 – Reset Gas Valve This will only appear after the gas valve has been shutoff and continues to produce a current to the thermopile. Turn the gas control dial to off and let sit for one minute. If the pilot remains lit you will need to replace the gas control valve.

How do I know if my pilot light is out?

  1. Locate the front cover panel on your furnace. It should be a little door that’s easily visible. …
  2. If your pilot light is on, it should be easy to see – your eyes will be drawn to the little flame.
  3. If you don’t see a flame, your pilot light is out.
  4. If there is a flame, check the color.

Where do you light a pilot?

Step 1: Find the pilot light assembly. It’s usually near the bottom of the furnace and has a gas valve with on, off, and pilot settings. Step 2: Turn the valve to off and wait three minutes.

Does an electric water heater have a pilot light?

There’s no gas or pilot light involved in electric water heaters. If the power to your electric water heater is off, you may have an electrical issue requiring professional assistance. You will not need to reignite the water heater if you have a newer model equipped with an automatic pilot light.

Should the pilot light always be on in a gas heater?

Leaving the gas on keeps this compound moving out of the tubes. Keeping the pilot light on will also keep moisture out of the unit and in turn, help prevent corrosion. … As you can see, it’s probably best in most cases to extinguish the pilot light in your gas fireplace during the months when you don’t need heat.

How do you light a gas water heater?

Turn the water heat dial to Low and the On/Off/Pilot dial to Pilot. Then, turn the On/Off/Pilot dial downwards and push the igniter button at the same time. Let go of the igniter button, but keep pressing the Pilot dial downward for around 30 seconds. You should hear a “whoosh” sound when the gas is lit.

Article first time published on

Should the water heater be on pilot or on?

You should set the water heater to “pilot”. If, however, your water heater is also the boiler for your central heating, then you’ll want to leave the heating running as normal so that your house doesn’t get damp as a result of cold and condensation.

How do you fix a gas fire that keeps going out?

  1. Before You Begin: Is Your Pilot Light Lit Inside Fireplace?
  2. The Fix: Pilot Light to Gas Fireplace Won’t Stay Lit.
  3. Check Your Thermopile Output with the TH/TP Contacts.
  4. Don’t Replace Your Thermopile or Thermocouple Right Away.
  5. Cleaning the Thermopile.
  6. Re-test the Cleaned Thermopile.

How do you know if you have a bad thermocouple?

If you can’t get the flame to light at all, and you’re sure the gas is on, there’s probably an obstruction in the pilot tube. If the flame lights and goes out when you release the gas control knob after holding it in for the recommended 20 to 30 seconds, that’s the sign of a thermocouple malfunction.

How do I know if my gas valve is bad on my furnace?

If 24 volts is coming from the board to the gas valve terminals and you don’t hear that little clicking noise the internal valve makes, you could have a bad gas valve. To double-check, take the leads off to the gas valve and check there.

How do you reset the gas valve on a water heater?

Turn the water heater’s gas valve switch to the “OFF” position, wait for a few seconds and then flip the switch to the “ON” position to reset the system. The water heater’s gas valve is located near the bottom of the unit and connects to your home’s natural gas line.

How do I reset my Honeywell?

  1. Power off the thermostat and remove the batteries.
  2. Put the batteries in the wrong way, with negative to positive and positive to negative.
  3. Wait ten seconds and put them back in the correct way.
  4. Your thermostat will be reset to factory settings.

How do you test a gas control valve?

  1. Turn off the furnace at the wall control. …
  2. Take out the bolts in the service panel on the side of the furnace using a nut driver. …
  3. Pull the wires off the gas valve terminals. …
  4. Turn the test control on the multimeter to “mV,” which stands for millivolt.

Why won't my pilot light light on my gas furnace?

There are several possible reasons why your gas furnace pilot won’t light: an ongoing draft, a faulty thermocouple, an accumulation of dirt, or an inefficient supply.

You Might Also Like